Print ISSN:-2395-1354

Online ISSN:-2395-1362

CODEN : IJOSHC


Article Metrics




Downlaod Files

   


Article Access statistics

Viewed: 726

PDF Downloaded: 1287


Functional and anatomical outcome of displaced intraarticular fractures of calcaneum treated using locking plate fixation


Full Text PDF Share on Facebook Share on Twitter


Original Article

Author Details : Somashekar , Jai Adiya Jhamb, Anudeep N Naik*

Volume : 6, Issue : 2, Year : 2020

Article Page : 111-116

https://doi.org/10.18231/j.ijos.2020.020



Suggest article by email

Get Permission

Abstract

Most calcaneal fractures are intraarticular fractures involving the posterior facet of the subtalar joint.
Treating displaced intraarticular calcaneal fractures is challenging due to the paucity in optimal treatment
options. Internal fixation typically involves screw-and-plate implants, which can be unfavourable owing
to the lack of an anatomic design and the intraoperative bending required for the plate to contour to the
irregular surface of the calcaneus. In our study we included fifteen patients, two were female and the rest
thirteen were male.
The mechanism of injury involved road traffic accident in two cases and fracture as a result of fall from
height in the remaining patients.
These patients were followed up for 6 months at the end of which functional outcome was assessed in all
patients using the Ankle-Hind foot scale, that included assessment of pain, function, maximum walking
distance, gait abnormality, graded difficulty in walking on different surfaces, motion, stability of ankle and
alignment of ankle and foot. Based on this scale 10 patients (66.6%) had good outcome, 4 patients had
fair outcome (26.6%) while 1 patient (6.66%) had poor outcome. The results were promising, revealing
that the anatomic locking plate can be used effectively in the treatment of displaced intraarticular calcaneal
fractures using simple reduction techniques with a potentially shortened operating time.

Keywords: Calcaneum.



How to cite : Somashekar, Jhamb J A, Naik A N, Functional and anatomical outcome of displaced intraarticular fractures of calcaneum treated using locking plate fixation. Indian J Orthop Surg 2020;6(2):111-116


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.