Print ISSN:-2395-1354

Online ISSN:-2395-1362

CODEN : IJOSHC


Article Metrics




Downlaod Files

   


Article Access statistics

Viewed: 2407

PDF Downloaded: 733


External fixator and K wire- A versatile tool in distal end radius fractures


Full Text PDF


Original Article

Author Details : Kaushal Anand, Hriday Acharya, Satvik Patel, Shalin Shah

Volume : 4, Issue : 1, Year : 2018

Article Page : 48-52

https://doi.org/10.18231/2395-1362.2018.0011



Suggest article by email

Get Permission

Abstract

Introduction: Distal end of the radius fractures are common injuries and are the commonest bony injury around the wrist. The logical treatment need to be planned based on specific fracture configuration, the extent of displacement, degree of articular disruption, stability and many other factors. The present study is intended to assess results of closed reduction, K wiring and external fixator in Fractures of Lower end Radius/ulna in 40 patients classified according to Frykman’s classification.
Materials and Methods: This is a retrospective study of 40 cases of distal end radius fractures selected randomly over a period one year from March 2016 to March 2017.
Observation and Results: Out of 40 patients in the study most of them were male with the mean age of patients being 44.72.Injury was commonly due to fall on out stretched hand with no associated injuries signifying it is caused by low energy trauma. Most of the patients were of Frykman type III and IV. The average period for intermittent mobilization is between 6 to 7 weeks. 90% patients have 10‐22 degrees of range of radial inclination. Most patients developed a good range of movement post-op.  Few complications were reported with pin tract infection being present in 5% cases.
Conclusion: We have studied 40 patients of distal end radial fracture treated with external fixator and K wires. It is simple and inexpensive implant. Technique is less demanding for surgery. It causes minimal soft tissue interference. Elbow and fingers can be mobilized immediate post operatively. It maintains reduction and provides stability to fracture fixation. Period of immobilization was short. Complication rates are comparatively low in our study. Most patients had excellent to good results. Its ease of use and successful results make external fixator and K wire versatile tool for treatment of these fractures.

Keywords: Distal end radius, External fixator, K wires.



How to cite : Anand K, Acharya H, Patel S, Shah S, External fixator and K wire- A versatile tool in distal end radius fractures. Indian J Orthop Surg 2018;4(1):48-52


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.