Surgical treatment of distal end of radius fracture with volar locking plate: Clinicoradiological outcome of 25 cases


Full Text PDF


Original Article

Author Details : Ejajahmed Ansari, Parag M. Tank*, Rajesh V. Chawda, Vijay J. Patel, Nimish B. Patel

Volume : 4, Issue : 3, Year : 2018

Article Page : 264-269

https://doi.org/10.18231/2395-1362.2018.0052



Suggest article by email

Get Permission

Abstract

Introduction: Distal radius reconstruction every time needs aggressive operative intervention is still a debate among researchers and upper extremity surgeons. There is a role of nonoperative treatment in geriatric population and unfit patients. Novel techniques and revolution of implants advocated the best clinical outcome.
Materials and Methods: We conducted a prospective study of 25 patients having AO OTA type A, B & C distal radius fractures treated with volar locking plate at our institute between 2015 to 2017. We include all close injuries in skeletally mature patients between ages 20-60 years. Outcome of the study was evaluated by using the Gartland and Werley score modified by Sarmiento & Patient Rated Wrist Evaluation (PRWE) score.

Results: 6 patients had AO OTA type A, 11 patients had type B and 8 patients had type C fractures. Mean palmar flexion was 77 degrees. Dorsi flexion was 82 degrees observed. Average supination and pronation were 85 & 80 degrees respectively. Radial & ulnar deviations average 11 and 25 degrees were observed. 80% of the patients had loss of radial inclination less than 9 degrees. All the patients had less than 6 mm radial shortening. Loss of palmar tilt less than 6 degrees was observed. More than 90% of the patients had excellent to good outcome based on Gartland and Werley score.
Conclusions: Volar plating is a proven method of choice in majority of distal end radius fractures regardless of comminution and fragments separation.

Keywords: Distal radius fractures, Internal fixation, Volar plate, AO OTA fractures.



How to cite : Ansari E, Tank P M, Chawda R V, Patel V J, Patel N B, Surgical treatment of distal end of radius fracture with volar locking plate: Clinicoradiological outcome of 25 cases. Indian J Orthop Surg 2018;4(3):264-269


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.