Print ISSN:-2395-1354

Online ISSN:-2395-1362

CODEN : IJOSHC


Article Metrics




Downlaod Files

   


Article Access statistics

Viewed: 1474

PDF Downloaded: 621


To evaluate efficacy and complications of suction drains in hemiarthroplasty cases


Full Text PDF


Original Article

Author Details : Vijay C*, Ravikiran HG, Sumit Raj

Volume : 4, Issue : 3, Year : 2018

Article Page : 286-289

https://doi.org/10.18231/2395-1362.2018.0056



Suggest article by email

Get Permission

Abstract

Introduction: Intracapsular fracture of neck femur usually present with severe swelling, difficulty in walking reduced length of affected limb. The most common Risk factors are old age, osteoporosis, taking excessive medications, alcohol, smoking and  cancer. Diagnosis can be done by using X-rays, CT scan and MRI.
Materials and Methods: It is a prospective study consists of all the patients admitted to JSS hospital with intracapsular fracture neck femur treated with unipolar or bipolar endoprosthesis.
Results: The selected patients were randomized and divided into two groups, Group one (I) and Group two (II). Patients were suction tube is used are categorized into Group I and in those were suction tube is not used are categorized into Group II. These two groups were studied and observed for the following, fall in haemoglobin and PCV at 48 hours post-operatively. Complications are Persistent discharge, serous discharge from the wound for more than 10 days.
Discussion: When the doctors are in doubt, then they need to insert a drain was countered by Halsted (1898). Now days in orthopedic cases, closed suction drains are being commonly used to decrease the complications. Blood accumulation in and around the tissue site will raise the tissue tension and thereby reduces tissue perfusion in and around the surgical wound site.
Conclusion: We consider that there is ample evidence that closed suction drains is of no benefit in primary uncomplicated hemiarthroplasty. The advantage of the drains in orthopaedic surgeries should be debated as non use of drains drastically reduces anemia and requirement of blood transfusion after surgery. In a developing and under-developing countries, the cost increases because of the blood transfusion needs and costs of drain device which will outweigh any advantages of putting a drain.

Keywords: Persistent discharge, Dressing reinforcements, Superficial surgical site infections, Blood transfusion.



How to cite : Vijay C, Ravikiran Hg, Raj S, To evaluate efficacy and complications of suction drains in hemiarthroplasty cases. Indian J Orthop Surg 2018;4(3):286-289


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.