Introduction
The tibial intra-articular fracture refers to soft tissues envelope and often known as pillion fracture. In such case an anatomic realignment of involved articular fracture in conjunctions with stable fixation is crucial. The major cause of this type of injury involves low energy and rotational forces as well as the position of the foot movement.1 This type of injury requires careful management of the soft tissues and appropriate system for reduction. The clinical assessment of the injury is essential for managing the issues and proper fixing of the bones. The process of fixing such fracture is involving the various modalities like soft tissue dehiscence, reduction of articular fragmentation with stable fixation through external devices. The use of olive wires enables the multi-directional forces to apply for the reduction of the spiral fracture.
In the treatment of fracture of the distal part of the tibia, care professional need to provide extra care as it involves a small group of fracture which cause difficulty in management and classification. Tibia is the major weight-bearing bone of the leg and open fractures are most common in this area of the body.2 The treatment of distal tibia fracture often results in several complications including malunion, non-union and ankle surface. The operative treatment of the tibial fracture is caused by high energy trauma and early motion of the tissues. The goal of treatment involves healed, well-aligned, functional range of motion of ankle joint. To offer the treatment the approach of fracture reduction has been successful in treating the complex fracture. The main objective of this technique is to apply stable plate fixation while maintaining the fracture biology and maintaining the soft tissue problem. In the current scenario, the trends towards using the locking plates are beneficial for managing the distal part of the tibia.3
The locking plates have the biomechanical properties of internal and external fixation that provide the superior holding power and fixed angular holding. In addition to this, the new techniques of treatment of such fracture involve the Minimally invasive percutaneous plate osteosynthesis which aims to minimal periosteal dissection and disruption of hematoma, stable anatomical fixation and early mobilization. These kinds of treatment techniques are having a significant impact on managing the high-energy fracture of the distal tibia. The research will provide the information related to the outcome of the intra- articular fracture of distal tibia treatment with an external fixator.4 This kind of injuries is challenging because of its subcutaneous location and precarious blood supply and proximity to the ankle joint. The proper analysis of injury and implementation of the treatment plan helps manage the issues and provide better care services to the patients. The initial radiography is required for determining the particular fracture pattern that could associate with the injury. The IM nailing has reported with higher rates of mal-union because nail cannot provide the tight fit at the distal fracture site and affect the process of offering the treatment.5
Aim
The research paper aims to analyze the outcome of communited intraarticular fractures of distal tibia treated with an external fixator.
Materials and Methods
The current study is an observational study that is being conducted in Dr. D.Y. Patil hospital, Navi Mumbai from May 2020 to May 2021. For the study, the researcher has selected 30 people that involve 23 male and 7 female. The mean age of these participants was 53 years (range between 26-72 years). Moreover, the researcher has used Muller-Nazarian classification for analyzing the results and used the clinical approach for identifying the impact of the surgery.
Results
For the current study, the researcher has used the observation and opinion method for analyzing the data collected from the different participants. The clinical outcome of the study involves the accuracy of reduction score mean points and external fixator.
Table 1
Anatomic |
8 points |
7 cases |
Good |
9-11 points |
22 cases |
Fair |
12-15 points |
1 case |
Poor |
<15 points |
- |
There were no diagnose for deep venous thrombosis and superficial pin tract infection was presented in the identified cases. The infection at 3 pin sites from the distal tibia ring was encountered in two cases and replaced with the wire and screw. The clinical result of study involves the mean score of 81.5 points that range between 58-100. The first requirement of arthrodesis of the ankle and this patient scored 9 points for reduction quality. The development of stiff ankle with equines of the foot from interruption of physiotherapy has helped to maintain the high standards in the treatment. The hospitals are following a myocardial infarction for analyzing the impact and recovery of the patients. However, the 34-year-old man with 43 C3 and the diaphyseal fracture was treated with the wire and plates to manage the issues. Moreover, the second poor result was 55 years old male who was addicted to smoke and it has affected the recovery process. The clinical results have identified that the patient was facing the issues related to A5 valgus deformity that also occurred with diabetes. The consideration of results focusing on the approach of external treatment was found good and applied for the other clinical studies of the patients.
Discussion
For managing the intraarticular fractures of the distal tibia is having a significant impact on the body function of the individual. The study has identified issues and approaches of treatments to identify the impact of the external fixator. According to Beytemür et al., (2017), the open reduction and internal fixation (ORIF) has led to variable results for high energy distal tibia.6 The reduction is stable and having a direct impact on the approaches of treatment offered to the different age people. As per the finding, 74% of cases were good and less than 5% of people found with an infection that influences the healing.7 However, without complications of deep infection and consideration of articular restoration can be beneficial for gaining a favourable outcome for the patients. The external fixation is allowing the care professionals to manage the fracture in 10-14 days by fixing the soft tissues and periosteum. This kind of approach is helpful for the stable reduction and reported that 55% of patients have achieved good results by applying this technique. However, Aurich, Koenig, and Hofmann, (2018) have stated that internal osteosynthesis of the tibia was performed in 56% cases and founded that greater infection rate. The lack of external support and lack of prevention of the soft tissues is hurting the recovery process of an individual.8 The quality of reduction and clinical outcome of the fracture group is having a radiography therapy for managing the issues that are helping to improve the situation.
For stable and healing of distal tibia, the patient needs to focus on the weight and physical activities. As per the views of Yoon et al., (2015), the B4 and B3 types of fracture patients are facing serious issues for improving the health. These kinds of fractures are treated with the only external fixator.9 The proper stabilization with rod and interior angulations that varying from 5 to 25 and can help provide effective care to the patients. Their rotational process for managing the external fixator is helpful for the natural position at the moment of impact. The low energy trauma and the fracture pattern is having a significant impact on the clinical treatment and management of the soft tissues and early fixation. This kind of treatment approach is useful for weight-bearing. However, the external fixator is having skin damage and secondary infection caused by the high energy trauma that influences the result of treatment and tibia shaft fracture. The poor results of internal treatment and lack of satisfaction among the patient is influencing the demand for external fixator treatment.10 The report has identified that the development of stiff ankle with equines of the foot from interruption of physiotherapy has helped to maintain the high standards in the treatment. The infection at 3 pin sites from the distal tibia ring was encountered in two cases and replaced with the wire and screw. In addition to this, joint surface resulting in forwarding dislocation and healing and setting the right position for increasing the stability.
Conclusion
From the study, it can be considered that external fixator treatment for communited intraarticular fractures of the distal tibia is beneficial and having a positive impact on the process of offering the required support to the patients. The proper analysis of health conditions of individual and treatment helps manage the operations.