Introduction
Femur is the largest bone in the body. Fractures of the femoral shaft often are the result of high energy trauma and may be associated with multiple injuries.1 Main goal of treatment is restoration of length, alignment, rotation, and preservation of blood supply and avoiding infection.2 There are various modalities for management of femur shaft fractures such as closed reduction and cast immobilization, skeletal traction, intramedullary nailing, interlocking intramedullary nailing (antegrade or retrograde) and plating. Locked intramedullary nailing is currently considered to be the treatment of choice for most femoral shaft fractures.3 Intramedullary nailing is preferred as plating has higher risk of infection and nonunion.4 Risk factors for femoral nonunion after intramedullary nailing are open fracture, fracture in distal third of femur treated with antegrade nailing, delay in weight bearing, and tobacco use.5 The treatment of nonunion with a statically locked intramedullary nail in place is either bone grafting in situ, dynamization of the nail by locking bolt removal, or exchange nailing.6 We combined exchange nailing augmented with plate and allografting to study its usefulness in treating femur shaft nonunion after nailing.
Table 1
Materials and Methods
We did a retrospective study. Cases were collected between Aug 2020-June 2022. 15 patients were collected, 10 men and 5 women. They had undergone intramedullary nailing for femur fracture. Fractures which went into nonunion after intramedullary nailing were typically either juxta-articular fractures i.e., either subtrochanteric fracture of femur or fractures in distal third of femur treated with antegrade femoral nailing with only 2 interlocking bolts in distal fragment. Infection was ruled out. Mean period for presentation of nonunion - 20 months after primary surgery. All the patients had uninfected nonunion. 10 patients had undergone intramedullary nailing with proximal and distal bolts locked, 3 had distal dynamized intramedullary nailing, 1 had breakage of proximal bolt of intramedullary nail and 1 had Kuntscher nail. Initially the old nail was removed. Reaming was done. Then we freshened the ends of the nonunion till the ends bled. Then we passed a nail, did distal interlocking with three bolts (two transverse and one anteroposterior) and then added a plate. Plate used was 4.5mm system 8–10-hole DCP contoured for femur. We used a muller device over the plate to compress the nonunion and added an allograft when needed. Minimum 3 screws in plate on either side of fracture were aimed. The nail was finally locked proximally.
Results
Table 4
Site of femur Nonunion |
Frequency |
Percentage |
Upper 1/3 |
3 |
20 |
Middle 1/3 |
7 |
46.6 |
Lower 1/3 |
5 |
33.3 |
Total |
15 |
100 |
All but one patient achieved postoperative bony union uneventfully at a mean time of 22.1weeks (range, 12–40 weeks). The mean operative time was 105 minutes (range, 60–150minutes), and the mean blood loss was 300 ml (range, 150–500 ml). Immediate weight bearing started as tolerated by patient. The 14 patients could walk bearing full weight without pain within 3 months. There were no significant complications such as broken hardware, implant back-out, axial or rotational malalignment, or deep infections in the successful united patient. One patient did not achieve union after the procedure.
Discussion
Achieving union of long bone diaphyseal fractures, away from isthmus of bone, where the medullary cavity is wide, remains a challenge.7 This is especially true when treated with intramedullary nailing. Because nailing is a load sharing device and provides only relative stability.8 Therefore, not adequate rotational stability is present where medullary canal is wide. On the other hand, plating does provide rigid fixation avoiding rotational instability.9 With plating, chances of implant breakage remain an issue as it is a load bearing implant.10 Both nail and plate alone are inadequate in treating nonunion of juxta articular long bone fractures. Combining plate which provides torsional stability with nail which provides axial and bending stability provides best chance of treating these nonunion. It is wwell-establishedthat to treat femur non unions one can go for exchange nailing augmented with plating. We combined the above with allograft to ensure union and avoid patient the pain of repeat surgery preventing additional morbidities associated with surgery. We used allograft when there was gap at fracture after nibbling of sclerosed edges of nonunion, and used local hypertrophic cancellous bone when gap was minimal. One should be generous while removing the sclerosed ends as failure to do so would prevent union despite of reaming exchange nailing augmented plating and allografting. We learnt this the hard way which led to one failure to unite in our study. Using Judet’s technique (1963), osteoperiosteal flaps were raised. This elevation of cortical chips that remains attached to the periosteum surrounding the non-union site physiologically helped in increasing the decorticated surface area (which acts as multiple fractures and induces bone formation), exposure of vascular subcortical Haversian system, Osteogenic stimulation by inflammation of mechanical origin and acts as ‘in situ’ vascularized autogenous bone graft. Other similar studies were done by ekre-echam, where they used exchange nailing and augmented plating as a combined procedure in two cases and achieved union in both; Wang et al. where they used thick interlocking nail augmented with plate fixed with unicortical screws only; and Sancheti et al. where they used exchange K-nailing augmented with plating fixed with bicortical screws and autograft. But our study differs from these in that we used interlocking nail and a mullers device to approximate the fracture ends and an allograft.